  • 84% AFUE 120000 Btuh Gas-Fired Water Boiler

    BWBCAN000120 B = Boiler W = Water Type of System B = Natural Draft/Electronic Combustion/Ignition C = Model Code A = 110 to 125 60 Hz Electrical N = Natural Gas Fuel 000 = Cooling 120 = 120000 Btu Input Heating Size The Model BWB Gas-Fired Hot Water Boiler provides fast heat quietly and economically to assure the finest in hydronic heating.

    Get Price
  • 75,000 BTU 85% AFUE Laars Hot Water Gas Boiler - Chimney ...

    Boiler Features. Hybrid Metal Heat Exchanger - The Mini-Therm uses a heat exchanger comprised of both cast iron and copper. Cast iron 'wet walls' add durability to the heat exchanger's construction while copper tubes facilitate high levels of heat transfer. Automatic Draft Hood -The JVS Mini-Therm comes with an automatic draft hood.

    Get Price
  • UH15C

    2021-10-1u2002·u2002The UH15C is available in two sizes from 262 MBH to 299 MBH and is designed for chimney-vent applications. With an efficiency of 84.0% AFUE, the latest design features a Hydrolevel FuelSmart control that monitors water temperature and delays burner start until residual heat has been transferred to the system for maximum efficiency. An integral Draft Hood and …

    Get Price
  • REPAIR PARTS AND OPTIONAL ACCESSORIES

    2020-7-30u2002·u2002Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES Ordering Instructions ... Split 7/8', #2874 * Sensor, 24' * Sensor Clip * Low Volt Harness * Line Volt Harness ... 34620601 Draft Hood (045) 1 34620602 Draft Hood (070, 096)

    Get Price
  • MASTER SPECIFICATIONS Division 23 HEATING

    2021-5-11u2002·u200223 6423 screw water chillers . 23 6500 cooling towers . 23 7313 packaged air handling units . 23 7323 factory fabricated custom air handling units . 23 8126 duct free split system air conditioners . 23 8216 coils . 23 8413 humidifiers ** end of list **

    Get Price
  • Series 63 Series 64 - PB Heat: Peerless® Boilers

    2020-8-11u2002·u2002or Split-Assembled (6-12 sections) > Boiler Reset Control with Low Water Cut-off for ... boiler for gravity hot water installations or for installations having unusual piping and pickup requirements such as exposed piping, night set-back, etc. Ratings ... *Draft hood outlet and vent damper are 7' diameter on 63-04L and 63.04. These models are ...

    Get Price
  • Chicago Steam & Hydronics - Specialists in the boiler room ...

    2021-9-4u2002·u2002Our manufacturing partners included Shipco, Tunstall, Macon, and more for the boiler room accessories. McKenna and Bosch boilers for the steam and hot water boilers along with Security Chimneys, Jeremias, Centrotherm, US Draft and many more for the necessary venting solutions. Our team can offer more than 100 years of combined experience.

    Get Price
  • DXL - Dunkirk

    2020-12-23u2002·u2002GAS FIRED BOILERS . FOR FORCED HOT WATER With Hydrolevel Control. Models. DXL-060K DXL-095K. DXL-120K DXL-150K . DXL-175K DXL-205K. DXL-235K. Manufactured by: ECR International Inc. 2201 Dwyer Avenue, Utica, NY 13501 Tel. 800 253 7900 www.ecrinternational.com PN 240012803 REV. C [11/15/2020] Ordering Instructions. Order Parts …

    Get Price
  • ITAZ RQ: Final Exam (Chapters 8-13) Flashcards by Ego Vero ...

    The safety control that prevents superheated water in a hot water boiler system is a. the circulator ... c. a draft hood d. an overcurrent protection device e. an induced draft fan ... Which of the following is NOT a common problem with a condensate collection system on a split-system air conditioner? a. the condensate does into a 3/4 inch ...

    Get Price
  • 84% AFUE 120000 Btuh Gas-Fired Water Boiler

    BWBCAN000120 B = Boiler W = Water Type of System B = Natural Draft/Electronic Combustion/Ignition C = Model Code A = 110 to 125 60 Hz Electrical N = Natural Gas Fuel 000 = Cooling 120 = 120000 Btu Input Heating Size The Model BWB Gas-Fired Hot Water Boiler provides fast heat quietly and economically to assure the finest in hydronic heating.

    Get Price
  • 75,000 BTU 85% AFUE Laars Hot Water Gas Boiler -

    Boiler Features. Hybrid Metal Heat Exchanger - The Mini-Therm uses a heat exchanger comprised of both cast iron and copper. Cast iron 'wet walls' add durability to the heat exchanger's construction while copper tubes facilitate high levels of heat transfer. Automatic Draft Hood -The JVS Mini-Therm comes with an automatic draft hood.

    Get Price
  • UTICA PEG-112EID, 112 MBH Steam Gas Boiler

    UTICA PEG411203100510 PEG-112-EID 112,500 BTU STEAM ELECTRONIC ING 5' FLUE. UTICA PEG-112EID, 112 MBH Steam Gas Boiler. Product Info. Product Info. Features/Benefits : Classic, Low Profile, Compact Design; Redesigned Textured Paint Jacket Features an Easy to Remove, 1-Piece Front Panel that Conceals and Protects the Electronic Ignition Control ...

    Get Price
  • REPAIR PARTS AND OPTIONAL ACCESSORIES

    2020-7-30u2002·u2002Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES Ordering Instructions ... Split 7/8', #2874 * Sensor, 24' * Sensor Clip * Low Volt Harness * Line Volt Harness ... 34620601 Draft Hood (045) 1 34620602 Draft Hood (070, 096)

    Get Price
  • Chicago Steam & Hydronics - Specialists in the boiler

    2021-9-4u2002·u2002Our manufacturing partners included Shipco, Tunstall, Macon, and more for the boiler room accessories. McKenna and Bosch boilers for the steam and hot water boilers along with Security Chimneys, Jeremias, Centrotherm, US Draft and many more for the necessary venting solutions. Our team can offer more than 100 years of combined experience.

    Get Price
  • MASTER SPECIFICATIONS Division 23 HEATING

    2021-5-11u2002·u200223 6423 screw water chillers . 23 6500 cooling towers . 23 7313 packaged air handling units . 23 7323 factory fabricated custom air handling units . 23 8126 duct free split system air conditioners . 23 8216 coils . 23 8413 humidifiers ** end of list **

    Get Price
  • Series 63 Series 64 - PB Heat: Peerless® Boilers

    2020-8-11u2002·u2002or Split-Assembled (6-12 sections) > Boiler Reset Control with Low Water Cut-off for ... boiler for gravity hot water installations or for installations having unusual piping and pickup requirements such as exposed piping, night set-back, etc. Ratings ... *Draft hood outlet and vent damper are 7' diameter on 63-04L and 63.04. These models are ...

    Get Price
  • DXL - Dunkirk

    2020-12-23u2002·u2002GAS FIRED BOILERS . FOR FORCED HOT WATER With Hydrolevel Control. Models. DXL-060K DXL-095K. DXL-120K DXL-150K . DXL-175K DXL-205K. DXL-235K. Manufactured by: ECR International Inc. 2201 Dwyer Avenue, Utica, NY 13501 Tel. 800 253 7900 www.ecrinternational.com PN 240012803 REV. C [11/15/2020] Ordering Instructions. Order …

    Get Price
  • ITAZ RQ: Final Exam (Chapters 8-13) Flashcards by Ego

    The safety control that prevents superheated water in a hot water boiler system is a. the circulator ... c. a draft hood d. an overcurrent protection device e. an induced draft fan ... Which of the following is NOT a common problem with a condensate collection system on a split-system air conditioner? a. the condensate does into a 3/4 inch ...

    Get Price
  • The Function of a Draft Diverter

    A draft diverter, or draft hood, plays a vital role in the operation of a combustion chamber, such as a fireplace or furnace. The draft diverter, which consists of a baffle plate positioned directly above the primary flue, regulates the direction and amount of air flowing in and out of the burner.

    Get Price
  • 75,000 BTU 85% AFUE Laars Hot Water Gas Boiler -

    Boiler Features. Hybrid Metal Heat Exchanger - The Mini-Therm uses a heat exchanger comprised of both cast iron and copper. Cast iron 'wet walls' add durability to the heat exchanger's construction while copper tubes facilitate high levels of heat transfer. Automatic Draft Hood -The JVS Mini-Therm comes with an automatic draft hood.

    Get Price
  • MASTER SPECIFICATIONS Division 23 HEATING

    2021-5-11u2002·u200223 6423 screw water chillers . 23 6500 cooling towers . 23 7313 packaged air handling units . 23 7323 factory fabricated custom air handling units . 23 8126 duct free split system air conditioners . 23 8216 coils . 23 8413 humidifiers ** end of list **

    Get Price
  • Water Heater Backdrafting, Part 1 of 2: Why it Matters and ...

    2013-9-24u2002·u2002An atmospherically vented water heater is a type with a draft hood, which relies on gravity to get the exhaust gases out of the home. Exhaust gas is hot and therefore lighter than the surrounding air, which is what allows it to rise up the vent and out of the house.

    Get Price
  • Chicago Steam & Hydronics - Specialists in the boiler

    2021-9-4u2002·u2002Our manufacturing partners included Shipco, Tunstall, Macon, and more for the boiler room accessories. McKenna and Bosch boilers for the steam and hot water boilers along with Security Chimneys, Jeremias, Centrotherm, US Draft and many more for the necessary venting solutions. Our team can offer more than 100 years of combined experience.

    Get Price
  • Series 63 Series 64 - PB Heat: Peerless® Boilers

    2020-8-11u2002·u2002or Split-Assembled (6-12 sections) > Boiler Reset Control with Low Water Cut-off for ... boiler for gravity hot water installations or for installations having unusual piping and pickup requirements such as exposed piping, night set-back, etc. Ratings ... *Draft hood outlet and vent damper are 7' diameter on 63-04L and 63.04. These models are ...

    Get Price
  • UTICA PEG-112EID, 112 MBH Steam Gas Boiler

    UTICA PEG411203100510 PEG-112-EID 112,500 BTU STEAM ELECTRONIC ING 5' FLUE. UTICA PEG-112EID, 112 MBH Steam Gas Boiler. Product Info. Product Info. Features/Benefits : Classic, Low Profile, Compact Design; Redesigned Textured Paint Jacket Features an Easy to Remove, 1-Piece Front Panel that Conceals and Protects the Electronic Ignition Control ...

    Get Price
  • Furnaces and Boilers

    2021-2-1u2002·u2002Steam boilers operate at a higher temperature than hot water boilers, and are inherently less efficient, but high-efficiency versions of all types of furnaces and boilers are currently available. To learn more about furnaces, boilers and other types of home heating systems, explore our Energy Saver 101 infographic on home heating.

    Get Price
  • Boiler Repair & Replacement in Buffalo

    2021-9-2u2002·u2002Radiators aren't getting hot. Caused by sludge or air buildup in the system. Boiler keeps turning itself off. Could be caused by a number of issues: low water pressure, thermostat issue, closed valve causing low water flow, air or pump not circulating water properly. A lack of regular tune-ups can often contribute to boiler breakdowns.

    Get Price
  • Fundamentals of Venting and Ventilation

    2007-1-15u2002·u2002The hot flue-gases would much rather travel up the relatively cool flue pipe than to 'back-track' to the much hotter main burner flame. The final force, which results from the heat which is created, ... As a result, flue products will spill out of the draft hood relief opening. Figure 4 …

    Get Price
  • The Function of a Draft Diverter

    A draft diverter, or draft hood, plays a vital role in the operation of a combustion chamber, such as a fireplace or furnace. The draft diverter, which consists of a baffle plate positioned directly above the primary flue, regulates the direction and amount of air flowing in and out of the burner.

    Get Price
  • Water Heater Backdrafting, Part 1 of 2: Why it Matters and ...

    2013-9-24u2002·u2002An atmospherically vented water heater is a type with a draft hood, which relies on gravity to get the exhaust gases out of the home. Exhaust gas is hot and therefore lighter than the surrounding air, which is what allows it to rise up the vent and out of the house.

    Get Price
  • MASTER SPECIFICATIONS Division 23 HEATING

    2021-5-11u2002·u200223 6423 screw water chillers . 23 6500 cooling towers . 23 7313 packaged air handling units . 23 7323 factory fabricated custom air handling units . 23 8126 duct free split system air conditioners . 23 8216 coils . 23 8413 humidifiers ** end of list **

    Get Price
  • HVAC Inspection Guide - InterNACHI House of Horrors

    The return register at the duct to the left of the furnace and at the ceiling is within 10 feet of the draft hood of the water heater tank located in the same space as the return register. Return air openings should be located at least 10 feet in any direction from a combustion chamber or draft hood on an fuel-burning appliance in the same room.

    Get Price
  • Mannix Heating & Air Conditioning Services

    Services. We work on any heating and cooling problem including emergency calls for your furnace, boiler, water heater, AC and Heat Pump. Service & Maintenance System Replacement Safety Inspections Services GasGas Fitting projects and gas leaks Water HeatersTank & Instant Water Heaters B ...

    Get Price
  • Range Hoods Archives - Superco Appliances, Furniture ...

    2021-9-24u2002·u2002FOTILE V Series 30″ 1000 CFM Range Hood with Touchscreen in Onyx Black Tempered Glass – JQG7505. $ 1,349.00. SAN YANG PAI Under Cabinet Hood – CY-88. $ 580.00 – $ 620.00. FOTILE 36″ 900 CFM Chimney Style Range Hood with Touchscreen – EMS9018. $ 1,499.00. FOTILE Pixie Air™ 30'' Slim Line Under the Cabinet Range Hood with ...

    Get Price
  • UTICA PEG-112EID, 112 MBH Steam Gas Boiler

    UTICA PEG411203100510 PEG-112-EID 112,500 BTU STEAM ELECTRONIC ING 5' FLUE. UTICA PEG-112EID, 112 MBH Steam Gas Boiler. Product Info. Product Info. Features/Benefits : Classic, Low Profile, Compact Design; Redesigned Textured Paint Jacket Features an Easy to Remove, 1-Piece Front Panel that Conceals and Protects the Electronic Ignition Control ...

    Get Price
  • Fundamentals of Venting and Ventilation

    2007-1-15u2002·u2002The hot flue-gases would much rather travel up the relatively cool flue pipe than to 'back-track' to the much hotter main burner flame. The final force, which results from the heat which is created, ... As a result, flue products will spill out of the draft hood relief opening. Figure 4 …

    Get Price
  • The Function of a Draft Diverter

    A draft diverter, or draft hood, plays a vital role in the operation of a combustion chamber, such as a fireplace or furnace. The draft diverter, which consists of a baffle plate positioned directly above the primary flue, regulates the direction and amount of air flowing in and out of the burner.

    Get Price
  • Utica UH1604HSID Gas-Fired Steam Boiler - 112,000 BTUS

    Utica UH1604HSID Gas-Fired Steam Boiler - 112,000 BTUS. The 16 Series features a dependable cast iron heat exchanger with cast iron push nipples. The sections and push nipples expand at the same rate when heated. By using similar materials instead of less expensive gaskets or steel push nipples, the boiler maintains a water tight seal.

    Get Price
  • Draft Regulators - Barometric Dampers: A Guide to ...

    at DRAFT HOOD, GAS HEATER for gas fired equipment. Define Barometric Damper or Draft Regulator. Barometric dampers are devices used to regulate the draft on oil-fired heating equipment such as furnaces, boilers, or water heaters. The barometric damper or draft regulating device we are discussing here is normally used only on oil-fired heating ...

    Get Price
  • Gas-Fired Boilers

    In a Category I gas-fired, natural-draft boiler, the natural draft of the heated flue pulls combustion air through the draft hood into the combustion chamber. (Source: Calcs Plus.) Figure 2. A Category I induced draft boiler uses an induced draft fan to pull air through the combustion chamber and to the flue. (Source: Calcs Plus.)

    Get Price
  • Induced Draft - an overview

    Swapan Basu, Ajay Kumar Debnath, in Power Plant Instrumentation and Control Handbook, 2015. 2.07.2 Induced Draught Fans. An induced draught fan (ID fan) is provided to maintain a negative pressure in the furnace by sucking the products of combustion from it with a slight positive pressure at the discharge end vis-à-vis the bottom of the chimney/stack.

    Get Price
  • IDENTIFICATION FOR PIPING AND EQUIPMENT

    2011-6-14u2002·u2002CP condensate pump HWB hot water boiler CT cooling tower HWHP hot water heating pump CUH cabinet unit heater P pump (other than those listed) CWP condenser water pump RF return fan EWH electric water heater SB steam boiler FHEX fume hood exhaust fan SF supply fan FP fire pump UH unit heater RHC reheat coil VP vacuum pump

    Get Price
  • Chapter 9: Installation of Specific Appliances, California ...

    Where hot-water-heating boilers are connected to heating coils located in air-handling units where they can be exposed to refrigerated air circulation, such boiler piping systems shall be equipped with flow control valves or other automatic means to prevent gravity circulation of the boiler water during the cooling cycle. [NFPA 54:10.3.9.2]

    Get Price
  • UTICA PEG-112EID, 112 MBH Steam Gas Boiler

    UTICA PEG411203100510 PEG-112-EID 112,500 BTU STEAM ELECTRONIC ING 5' FLUE. UTICA PEG-112EID, 112 MBH Steam Gas Boiler. Product Info. Product Info. Features/Benefits : Classic, Low Profile, Compact Design; Redesigned Textured Paint Jacket Features an Easy to Remove, 1-Piece Front Panel that Conceals and Protects the Electronic Ignition Control ...

    Get Price
  • NYC Department of Education

    2020-9-15u2002·u2002Boiler System Hot Water Boiler Instance on Basement Does not Exist Modular Boiler Instance on Basement Inspected Instance Boiler Room Instance Condition 3 - Fair Instance Quantity 882 Instance Quantity Uom MBH Net Instance Manufacturer Peerless Equipment 83100-01 Capacity/Size Quantity 882 Capacity/Size UOM MBH Net Source of Capacity/Size ...

    Get Price
  • NYC Department of Education

    2020-9-15u2002·u2002Domestic Hot Water System Inspected Domestic Hot Water Remote Storage Tank Inspected Condition 1 - Good Deficiency No deficiencies recorded Domestic Water Heat Exchanger Does not Exist NYC Department of Education Mechanical Inspection Building Condition Assessment Survey 2019 - 2020 K188 PB/A&W Page 3 of 11 Print Date: 9/15/2020

    Get Price
  • ITAZ RQ: Final Exam (Chapters 8-13) Flashcards by Ego Vero ...

    The safety control that prevents superheated water in a hot water boiler system is a. the circulator ... c. a draft hood d. an overcurrent protection device e. an induced draft fan ... Which of the following is NOT a common problem with a condensate collection system on a split-system air conditioner? a. the condensate does into a 3/4 inch ...

    Get Price
  • Mechanical CAD Details

    2009-12-21u2002·u2002hot water supply ~ j-i-----readfrom floor (range 0-200df) isolation gate /; ~.~.pipe union (typ)~old water supply valve(typ)~~ ~ t t electric water heater----~ n p&t relief valve f-----n (setting by mfr. of heater) cy--full size of valve outlet drain n fin.fl~o {route tempt. and press. valve <- outlet to 15 cm off floor or to floor drain when ...

    Get Price
  • HVAC Flashcards

    Test for spillage at the draft hood. ... What is the safety control that prevents 'superheated' water in a HOT WATER BOILER SYSTEM? ... Which of the following IS NOT a common problem with a condensate collection system on a split system air conditioner? a. Condensate goes into a 3/4 inch drain line b. Pan leaking

    Get Price
  • Gas-Fired Boilers

    In a Category I gas-fired, natural-draft boiler, the natural draft of the heated flue pulls combustion air through the draft hood into the combustion chamber. (Source: Calcs Plus.) Figure 2. A Category I induced draft boiler uses an induced draft fan to pull air through the …

    Get Price
  • Induced Draft - an overview

    Swapan Basu, Ajay Kumar Debnath, in Power Plant Instrumentation and Control Handbook, 2015. 2.07.2 Induced Draught Fans. An induced draught fan (ID fan) is provided to maintain a negative pressure in the furnace by sucking the products of combustion from it with a slight positive pressure at the discharge end vis-à-vis the bottom of the chimney/stack.

    Get Price
  • IDENTIFICATION FOR PIPING AND EQUIPMENT

    2011-6-14u2002·u2002CP condensate pump HWB hot water boiler CT cooling tower HWHP hot water heating pump CUH cabinet unit heater P pump (other than those listed) CWP condenser water pump RF return fan EWH electric water heater SB steam boiler FHEX fume hood exhaust fan SF supply fan FP fire pump UH unit heater RHC reheat coil VP vacuum pump

    Get Price
  • Chapter 9: Installation of Specific Appliances, California ...

    Where hot-water-heating boilers are connected to heating coils located in air-handling units where they can be exposed to refrigerated air circulation, such boiler piping systems shall be equipped with flow control valves or other automatic means to prevent gravity circulation of the boiler water during the cooling cycle. [NFPA 54:10.3.9.2]

    Get Price
  • UTICA PEG-112EID, 112 MBH Steam Gas Boiler

    UTICA PEG411203100510 PEG-112-EID 112,500 BTU STEAM ELECTRONIC ING 5' FLUE. UTICA PEG-112EID, 112 MBH Steam Gas Boiler. Product Info. Product Info. Features/Benefits : Classic, Low Profile, Compact Design; Redesigned Textured Paint Jacket Features an Easy to Remove, 1-Piece Front Panel that Conceals and Protects the Electronic Ignition Control ...

    Get Price
  • NYC Department of Education

    2020-9-15u2002·u2002Boiler System Hot Water Boiler Instance on Basement Does not Exist Modular Boiler Instance on Basement Inspected Instance Boiler Room Instance Condition 3 - Fair Instance Quantity 882 Instance Quantity Uom MBH Net Instance Manufacturer Peerless Equipment 83100-01 Capacity/Size Quantity 882 Capacity/Size UOM MBH Net Source of Capacity/Size ...

    Get Price
  • NYC Department of Education

    2020-9-15u2002·u2002Domestic Hot Water System Inspected Domestic Hot Water Remote Storage Tank Inspected Condition 1 - Good Deficiency No deficiencies recorded Domestic Water Heat Exchanger Does not Exist NYC Department of Education Mechanical Inspection Building Condition Assessment Survey 2019 - 2020 K188 PB/A&W Page 3 of 11 Print Date: 9/15/2020

    Get Price
  • ITAZ RQ: Final Exam (Chapters 8-13) Flashcards by Ego

    The safety control that prevents superheated water in a hot water boiler system is a. the circulator ... c. a draft hood d. an overcurrent protection device e. an induced draft fan ... Which of the following is NOT a common problem with a condensate collection system on a split-system air conditioner? a. the condensate does into a 3/4 inch ...

    Get Price
  • Mechanical CAD Details

    2009-12-21u2002·u2002hot water supply ~ j-i-----readfrom floor (range 0-200df) isolation gate /; ~.~.pipe union (typ)~old water supply valve(typ)~~ ~ t t electric water heater----~ n p&t relief valve f-----n (setting by mfr. of heater) cy--full size of valve outlet drain n fin.fl~o {route tempt. and press. valve <- outlet to 15 cm off floor or to floor drain when ...

    Get Price
  • HVAC Flashcards

    Test for spillage at the draft hood. ... What is the safety control that prevents 'superheated' water in a HOT WATER BOILER SYSTEM? ... Which of the following IS NOT a common problem with a condensate collection system on a split system air conditioner? a. Condensate goes into a 3/4 inch drain line b. Pan leaking

    Get Price