uganda steam boiler draft hood

Just fill in the form below, click submit, you will get the price list, and we will contact you within one working day. Please also feel free to contact us via email or phone. (* is required).

  • GAS-FIRED STEAM BOILER - dunkirk.com

    2021-8-16u2002·u2002Ivativ E D D www.dunkirk.com 240009797 ev GAS-FIRED STEAM BOILER PSB CAST IRON UP TO 82.7% AFUE EFFICIENCY 7 Models Available, 75 - 299 MBH Dependable Cast Iron Heat Exchanger with Cast Iron Push Nipples: The sections and push nipples expand at …

    Get Price
  • GAS-FIRED STEAM BOILER - Utica Boilers

    2020-10-23u2002·u2002Sensor, Integral Draft Hood, Vent Damper. Electrical: 24 Volt, 24VA Transformer. Safety: Blocked Vent and Rollout Safety Switches, Pop Safety Valve. Other: Crated Cast Iron Boiler with Insulated Jacket; Boiler Drain. OPTIONS Natural Gas or Propane. Electronic Water Feeder, Manual Reset Pressure Switch and LWCO A SAFETY RELIEF VALVE B C 29' 2 ...

    Get Price
  • Hydronic Heating Products - Utica Boilers

    2015-8-25u2002·u2002The PEG-C Steam boilers, in six sizes, are the ideal selection for steam system replacement or upgrade. Features such as cast iron heat exchangers and push ... front access door and integral draft hood make the JC boiler easy to install, clean and service. Pre-assembled burner and base units Tested for 100 lbs. ASME working pressure water, 15 ...

    Get Price
  • STEAM BOILERS - Slantfin

    2020-4-29u2002·u2002B. Boiler vent pipe must be the full diameter of the boiler draft hood outlet. See dimensions, page 2. If a vent damper is added, its diameter must be equal to the hood outlet and must be located past the hood outlet. See installation instructions furnished with vent damper and in the section 'Vent Damper Installation' of this instruction book. C.

    Get Price
  • Lifetime Limited Warranty GALAXY GALAXY II

    2021-1-18u2002·u2002the total capacity will Galaxy GXHA steam models do not require an external draft vary with the boiler hood. A built-in integral draft diverter on the four GXHA mod size. Available on els reduce clearance requirements above the boiler to 18', GXHII Series hot water making them ideal for use in locations with low chimney or GXH steam boilers.

    Get Price
  • Residential Steam Boilers

    2021-3-4u2002·u2002expensive gaskets or steel push nipples, the boiler maintains a water tight seal. Efficiency: The 16 Series provides an annual fuel utilization efficiency (AFUE) of up to 82.7% as certified by the US Department of Energy. Easy Installation and Maintenance: The 16 Series features an integral Draft Hood and Vent Damper.

    Get Price
  • BS2AAN000225 Gas Steam Boiler, 80% 225000 BTUH Heat

    BS1/BS2 Gas-Fired Comfort 80 Steam Boilers. For use with natural gas and are field convertible for use with propane gas with a factory authorized accessory conversion kit.Available 75,000 through 299,000 input BTUH. Standard Features. Fully assembled and pre-wired; Integral draft hood; Heavy duty cast iron sections and push nipples; Pressure ...

    Get Price
  • Performance Rating of Commercial Space Heating Boilers

    2015-5-11u2002·u20023.10 Draft Hood. A non-adjustable device, either built into or external to the Boiler, that is designed to (1) provide for the exhaust of the products of combustion in the event of no draft, back draft, or stoppage beyond the Draft Hood, (2) prevent a back draft from entering the Firebox, and (3) neutralize the effect of stack action of the

    Get Price
  • GMGS Series - Gas-Fired Steam Boiler

    The Sections and Push Nipples expand at the same rate when heated. By using similar materials instead of less expensive gaskets, the boiler maintains a water tight seal over time. LWCO (Probe Type), Pressure High Limit Control, Pressure Gauge, Gauge Glass. Atmospheric Chimney Vent Boiler with Integral Draft Hood and Vent Damper.

    Get Price
  • Series 63 Series 64 - PB Heat: Peerless® Boilers

    2020-8-11u2002·u2002Packaged or Knockdown, Hot Water or Steam Boilers ... *Draft hood outlet and vent damper are 7' diameter on 63-04L and 63.04. These models are also certified in USA with 6' vent using vent reducer provided in draft hood carton. Install reducer on outlet of vent damper. Title:

    Get Price
  • Performance Rating of Commercial Space Heating Boilers

    2015-5-11u2002·u20023.10 Draft Hood. A non-adjustable device, either built into or external to the Boiler, that is designed to (1) provide for the exhaust of the products of combustion in the event of no draft, back draft, or stoppage beyond the Draft Hood, (2) prevent a back draft from entering the Firebox, and (3) neutralize the effect of stack action of the

    Get Price
  • Residential Steam Boilers

    2021-3-4u2002·u2002expensive gaskets or steel push nipples, the boiler maintains a water tight seal. Efficiency: The 16 Series provides an annual fuel utilization efficiency (AFUE) of up to 82.7% as certified by the US Department of Energy. Easy Installation and Maintenance: The 16 Series features an integral Draft Hood and Vent Damper.

    Get Price
  • GAS-FIRED STEAM BOILER - dunkirk.com

    2021-8-16u2002·u2002Ivativ E D D www.dunkirk.com 240009797 ev GAS-FIRED STEAM BOILER PSB CAST IRON UP TO 82.7% AFUE EFFICIENCY 7 Models Available, 75 - 299 MBH Dependable Cast Iron Heat Exchanger with Cast Iron Push Nipples: The sections and push nipples expand at …

    Get Price
  • Lifetime Limited Warranty GALAXY GALAXY II

    2021-1-18u2002·u2002the total capacity will Galaxy GXHA steam models do not require an external draft vary with the boiler hood. A built-in integral draft diverter on the four GXHA mod size. Available on els reduce clearance requirements above the boiler to 18', GXHII Series hot water making them ideal for use in locations with low chimney or GXH steam boilers.

    Get Price
  • Manual of Procedures, Volume 1, Chapter 5 DRAFT

    2013-1-15u2002·u2002ii. Draft above draft hood or barometric damper (at high, medium & low fire) iii. Steam pressure, water temperature, or process fluid pressure or temperature entering and leaving the boiler, steam generator, or process heater. iv. Unit rate if meter is available. With the above conditions recorded, make the following checks and corrective ...

    Get Price
  • PARKER INDUSTRIAL HORIZONTAL DRUM STEAM

    2015-5-18u2002·u2002spec. sheet d-103-ie parker industrial horizontal drum steam boiler 0k4 7 to 25 h.p. – atmospheric gas fired - outdoor model d-103-ie.doc model no. 103-7 103-9.5 103-15 103-20 103-25 no. horsepower 7 hp 9.5 hp* 15 hp 20 hp 25 hp** a btu input 1000's btu/hr. 301 398 645 860 1075

    Get Price
  • Boiler Stack Breeching and Venting - GP Energy Products

    These boilers are typically used in buildings designed around a 130°F average water temperature. Category III —forced draft non-condensing boiler. These boilers are used in steam systems and hot water heating applications over 130°F average water temperature. Category IV …

    Get Price
  • Chicago Steam & Hydronics - Specialists in the boiler

    2021-9-4u2002·u2002Chicago Steam & Hydronics was established in March of 2020 with the vision to provide technical expertise and high-quality products for the steam and hydronics industry in the Chicagoland market. Our manufacturing partners included Shipco, Tunstall, Macon, and more for …

    Get Price
  • Draft hoods, Stack dampers and Standby losses — Heating ...

    January 2003. Draft hoods, Stack dampers and Standby losses. Looking at a steam boiler install where standby losses are a major issue and it got me thinking again (Oh, no!). I understand that stack dampers help eliminate losses through the stack through the draft hood relief opening from the boiler room. However, even with the stack closed on ...

    Get Price
  • Chimney Draft Calculator

    Chimney Draft Calculator: Chimney draft is required to draw the flue gases from the system and in order to prevent the backflow of gases the draft generated by chimney must be calculated accurately.Chimney draft depends on the following factors as mentioned below:-. Density of gases at the inlet of the chimney – Flue gases density at the inlet of the chimney is dependent upon the temperature ...

    Get Price
  • Performance Rating of Commercial Space Heating Boilers

    2015-5-11u2002·u20023.10 Draft Hood. A non-adjustable device, either built into or external to the Boiler, that is designed to (1) provide for the exhaust of the products of combustion in the event of no draft, back draft, or stoppage beyond the Draft Hood, (2) prevent a back draft from entering the Firebox, and (3) neutralize the effect of stack action of the

    Get Price
  • Inspecting Gas-Fired Boilers - InterNACHI®

    2020-1-31u2002·u2002The boiler in Figure 6 uses the older technology of a draft hood, which pulls dilution air into the vent pipe. The newer boiler in Figure 6 replaces the draft hood with a small induced-draft fan that pulls the products of combustion through the combustion chamber and flue by pushing the byproducts of combustion out through the vent pipe.

    Get Price
  • Residential Steam Boilers

    2021-3-4u2002·u2002expensive gaskets or steel push nipples, the boiler maintains a water tight seal. Efficiency: The 16 Series provides an annual fuel utilization efficiency (AFUE) of up to 82.7% as certified by the US Department of Energy. Easy Installation and Maintenance: The 16 Series features an integral Draft Hood and Vent Damper.

    Get Price
  • GSA Boiler Manual - Williamson-Thermoflo

    2019-12-12u2002·u2002GSA Gas-Fired Steam Boilers – Boiler Manual 4 Part Number 550-110-738/0319 1 Prepare boiler location continued Vent System Failure to follow all instructions can result in flue gas spillage and carbon monoxide emissions, causing severe personal injury or death.

    Get Price
  • Annual Low Pressure Boiler Inspection Review List

    2021-7-29u2002·u2002For cast iron boilers the feed water shall not be introduced through openings or connections used for relief, water column, or water level gage glass. NYS Rule 4-13.4 (d), 4-14.4 (b) and 4-5.9. A check valve shall be installed in a city water feed line for steam boilers…

    Get Price
  • User's Information Manual - Slant/Fin

    2020-4-29u2002·u2002DRAFT HOOD BLOCKED VENT SAFETY SWITCH PRESSURE RELIEF VALVE RETURN Location and identification of parts (Front panel removed) BRACKET FOR HYDROSTAT CONTROL HYDROSTAT CONTROL MODEL 3200-03 BEZEL THERMOSTAT TERMINAL ALTERNATE 1-1/2' RETURN (EXCEPT GG-7 THRU GG-175) Temperature and Pressure Gauge Jacket Top Figure 15. GXH Series—Steam Boiler

    Get Price
  • Series 63 Series 64 - PB Heat: Peerless® Boilers

    2020-8-11u2002·u2002Packaged or Knockdown, Hot Water or Steam Boilers ... *Draft hood outlet and vent damper are 7' diameter on 63-04L and 63.04. These models are also certified in USA with 6' vent using vent reducer provided in draft hood carton. Install reducer on outlet of vent damper. Title:

    Get Price
  • SIZING HANDBOOK & APPLICATION GUIDE

    2016-1-19u2002·u2002Both draft hood and fan-assisted combustion appliances may be 'listed' as Category I gas-burning equipment. The categorization process for residential gas furnaces and boilers now in effect is one part of the effort to provide venting provisions which match appliance operating features. Some important

    Get Price
  • Chimney Sizing

    2013-12-19u2002·u2002Natural Gas Draft Hood 1.60 Natural Gas No Draft Hood 0.90 LP Gas Draft Hood 1.64 Oil All 1.24 Oil #2 Over 400,000 BTU/hr 0.85 Oil #6 Over 400,000 BTU/hr 0.86 Coal (Bituminous) All 1.54 Conversion Factors Table 5 BTU/hr Input = Boiler Horsepower @100% efficiency x 33475 ' Boiler Horsepower @ 80% efficiency x 42000 ' Boiler Horsepower @75% ...

    Get Price
  • The Function of a Draft Diverter

    A draft diverter, or draft hood, plays a vital role in the operation of a combustion chamber, such as a fireplace or furnace. The draft diverter, which consists of a baffle plate positioned directly above the primary flue, regulates the direction and amount of air flowing in and out of the burner.

    Get Price
  • Performance Rating of Commercial Space Heating Boilers

    2015-5-11u2002·u20023.10 Draft Hood. A non-adjustable device, either built into or external to the Boiler, that is designed to (1) provide for the exhaust of the products of combustion in the event of no draft, back draft, or stoppage beyond the Draft Hood, (2) prevent a back draft from entering the Firebox, and (3) neutralize the effect of stack action of the

    Get Price
  • Inspecting Gas-Fired Boilers - InterNACHI®

    2020-1-31u2002·u2002The boiler in Figure 6 uses the older technology of a draft hood, which pulls dilution air into the vent pipe. The newer boiler in Figure 6 replaces the draft hood with a small induced-draft fan that pulls the products of combustion through the combustion chamber and flue by pushing the byproducts of combustion out through the vent pipe.

    Get Price
  • Residential Steam Boilers

    2021-3-4u2002·u2002expensive gaskets or steel push nipples, the boiler maintains a water tight seal. Efficiency: The 16 Series provides an annual fuel utilization efficiency (AFUE) of up to 82.7% as certified by the US Department of Energy. Easy Installation and Maintenance: The 16 Series features an integral Draft Hood and Vent Damper.

    Get Price
  • GSA Boiler Manual - Williamson-Thermoflo

    2019-12-12u2002·u2002GSA Gas-Fired Steam Boilers – Boiler Manual 4 Part Number 550-110-738/0319 1 Prepare boiler location continued Vent System Failure to follow all instructions can result in flue gas spillage and carbon monoxide emissions, causing severe personal injury or death.

    Get Price
  • Annual Low Pressure Boiler Inspection Review List

    2021-7-29u2002·u2002For cast iron boilers the feed water shall not be introduced through openings or connections used for relief, water column, or water level gage glass. NYS Rule 4-13.4 (d), 4-14.4 (b) and 4-5.9. A check valve shall be installed in a city water feed line for steam boilers. NYS Code 4-5.9

    Get Price
  • User's Information Manual - Slant/Fin

    2020-4-29u2002·u2002DRAFT HOOD BLOCKED VENT SAFETY SWITCH PRESSURE RELIEF VALVE RETURN Location and identification of parts (Front panel removed) BRACKET FOR HYDROSTAT CONTROL HYDROSTAT CONTROL MODEL 3200-03 BEZEL THERMOSTAT TERMINAL ALTERNATE 1-1/2' RETURN (EXCEPT GG-7 THRU GG-175) Temperature and Pressure Gauge Jacket Top Figure 15. GXH Series—Steam Boiler

    Get Price
  • Series 63 Series 64 - PB Heat: Peerless® Boilers

    2020-8-11u2002·u2002Packaged or Knockdown, Hot Water or Steam Boilers ... *Draft hood outlet and vent damper are 7' diameter on 63-04L and 63.04. These models are also certified in USA with 6' vent using vent reducer provided in draft hood carton. Install reducer on outlet of vent damper. Title:

    Get Price
  • SIZING HANDBOOK & APPLICATION GUIDE

    2016-1-19u2002·u2002Both draft hood and fan-assisted combustion appliances may be 'listed' as Category I gas-burning equipment. The categorization process for residential gas furnaces and boilers now in effect is one part of the effort to provide venting provisions which match …

    Get Price
  • Chimney Sizing

    2013-12-19u2002·u2002Natural Gas Draft Hood 1.60 Natural Gas No Draft Hood 0.90 LP Gas Draft Hood 1.64 Oil All 1.24 Oil #2 Over 400,000 BTU/hr 0.85 Oil #6 Over 400,000 BTU/hr 0.86 Coal (Bituminous) All 1.54 Conversion Factors Table 5 BTU/hr Input = Boiler Horsepower @100% efficiency x 33475 ' Boiler Horsepower @ 80% efficiency x 42000 ' Boiler Horsepower @75% ...

    Get Price
  • The Function of a Draft Diverter

    A draft diverter, or draft hood, plays a vital role in the operation of a combustion chamber, such as a fireplace or furnace. The draft diverter, which consists of a baffle plate positioned directly above the primary flue, regulates the direction and amount of air flowing in and out of the burner.

    Get Price
  • Performance Rating of Commercial Space Heating Boilers

    2015-5-11u2002·u20023.10 Draft Hood. A non-adjustable device, either built into or external to the Boiler, that is designed to (1) provide for the exhaust of the products of combustion in the event of no draft, back draft, or stoppage beyond the Draft Hood, (2) prevent a back draft from entering the Firebox, and (3) neutralize the effect of stack action of the

    Get Price
  • Inspecting Gas-Fired Boilers - InterNACHI®

    2020-1-31u2002·u2002The boiler in Figure 6 uses the older technology of a draft hood, which pulls dilution air into the vent pipe. The newer boiler in Figure 6 replaces the draft hood with a small induced-draft fan that pulls the products of combustion through the combustion chamber and flue by pushing the byproducts of combustion out through the vent pipe.

    Get Price
  • Residential Steam Boilers

    2021-3-4u2002·u2002expensive gaskets or steel push nipples, the boiler maintains a water tight seal. Efficiency: The 16 Series provides an annual fuel utilization efficiency (AFUE) of up to 82.7% as certified by the US Department of Energy. Easy Installation and Maintenance: The 16 Series features an integral Draft Hood and Vent Damper.

    Get Price
  • GSA Boiler Manual - Williamson-Thermoflo

    2019-12-12u2002·u2002GSA Gas-Fired Steam Boilers – Boiler Manual 4 Part Number 550-110-738/0319 1 Prepare boiler location continued Vent System Failure to follow all instructions can result in flue gas spillage and carbon monoxide emissions, causing severe personal injury or death.

    Get Price
  • Annual Low Pressure Boiler Inspection Review List

    2021-7-29u2002·u2002For cast iron boilers the feed water shall not be introduced through openings or connections used for relief, water column, or water level gage glass. NYS Rule 4-13.4 (d), 4-14.4 (b) and 4-5.9. A check valve shall be installed in a city water feed line for steam boilers…

    Get Price
  • User's Information Manual - Slant/Fin

    2020-4-29u2002·u2002DRAFT HOOD BLOCKED VENT SAFETY SWITCH PRESSURE RELIEF VALVE RETURN Location and identification of parts (Front panel removed) BRACKET FOR HYDROSTAT CONTROL HYDROSTAT CONTROL MODEL 3200-03 BEZEL THERMOSTAT TERMINAL ALTERNATE 1-1/2' RETURN (EXCEPT GG-7 THRU GG-175) Temperature and Pressure Gauge Jacket Top Figure 15. GXH Series—Steam Boiler

    Get Price
  • Series 63 Series 64 - PB Heat: Peerless® Boilers

    2020-8-11u2002·u2002Packaged or Knockdown, Hot Water or Steam Boilers ... *Draft hood outlet and vent damper are 7' diameter on 63-04L and 63.04. These models are also certified in USA with 6' vent using vent reducer provided in draft hood carton. Install reducer on outlet of vent damper. Title:

    Get Price
  • SIZING HANDBOOK & APPLICATION GUIDE

    2016-1-19u2002·u2002Both draft hood and fan-assisted combustion appliances may be 'listed' as Category I gas-burning equipment. The categorization process for residential gas furnaces and boilers now in effect is one part of the effort to provide venting provisions which match appliance operating features. Some important

    Get Price
  • Chimney Sizing

    2013-12-19u2002·u2002Natural Gas Draft Hood 1.60 Natural Gas No Draft Hood 0.90 LP Gas Draft Hood 1.64 Oil All 1.24 Oil #2 Over 400,000 BTU/hr 0.85 Oil #6 Over 400,000 BTU/hr 0.86 Coal (Bituminous) All 1.54 Conversion Factors Table 5 BTU/hr Input = Boiler Horsepower @100% efficiency x 33475 ' Boiler Horsepower @ 80% efficiency x 42000 ' Boiler Horsepower @75% ...

    Get Price
  • The Function of a Draft Diverter

    A draft diverter, or draft hood, plays a vital role in the operation of a combustion chamber, such as a fireplace or furnace. The draft diverter, which consists of a baffle plate positioned directly above the primary flue, regulates the direction and amount of air flowing in and out of the burner.

    Get Price
  • Intermediate Steam Boiler Operator Training

    Intermediate Steam Boiler Operator Training is a 5-day intermediate course that begins with an overview of topics covered in the Basic Steam Boiler Operator course. Intermediate Steam Boiler Operator Training expands knowledge of boiler operation theory, design and construction, steam distribution systems including piping and pressure reducing ...

    Get Price
  • Basic Steam Boiler Operator Training

    Basic Steam Boiler Operation, is a 5-day course providing information on virtually all facets of steam boiler operation, maintenance, and troubleshooting. Common boiler auxiliaries and operating techniques are covered in detail. Safety and efficiency of operation are stressed.

    Get Price
  • RULE 4304 EQUIPMENT TUNING PROCEDURE FOR

    2017-12-22u2002·u2002ii. Draft above draft hood or barometric damper 1) Draft hood: high, medium, and low 2) Barometric damper: high, medium, and low iii. Steam pressure, water temperature, or process fluid pressure or temperature entering and leaving the boiler, steam generator, or process heater. iv. Unit rate if meter is available.

    Get Price
  • Large Commercial Steam Boilers - P C McKenzie Company

    2017-1-26u2002·u2002Boiler Ratings - Packaged Series 211A™ Boiler Model Number Natural Gas Ratings Thermal Efficiency, % Combustion Efficiency, % Input, MBH Output¹, MBH Net Ratings² Steam EDR, sqft Steam, MBH 211A-04 630 486 1,521 365 77.1 79.8 211A-05 840 666 2,083 500 77.4 80.0 211A-06 1,050 816 2,550 612 77.7 80.0 211A-07 1,260 980 3,063 735 77.8 80.0

    Get Price
  • Ohio Boiler Sales, Boiler Service and Boiler Equipment

    2021-9-29u2002·u2002Shot feeders, injection quills, and sample coolers. Visit A&F's website for full product specifications. Boiler Specialists, Inc. can supply all of the A&F Machine and Helwig pump products needed in Northern Ohio. Contact one of our service or sales specialists at (216) 251-5151 for help with your A&F Helwig pump system.

    Get Price
  • Series 16H - Velocity Boiler Works

    Series 16H. The Series 16H is a commercial, cast-iron, gas-fired, hot-water boiler with thermal efficiency ratings of up to 81%. The Series 16H is designed for use with a conventional chimney. The boiler is packaged with an electronic ignition system for use with natural gas. The Series 16H is available in 4 sizes, with firing rates from 340 to ...

    Get Price
  • Steam Boiler Questions and Answers

    2021-6-13u2002·u2002Question: Steam valves open causing a sudden large load I have two 82,000 lb/hr natural gas fired boiler that is designed for 300 psig and operating at 205 psig (saturated). The boilers serve a large campus with numerous buildings, each with an integrated building management control system.

    Get Price
  • Fireside Boiler Cleaning - Controlled Combustion

    Inspect the chamber, interior draft hood, insulation, and burner ribbons. Reinstall cleaned burner ribbons, flue cover, top jacket panel, draft hood, and replace fireside gaskets as necessary to properly secure the fireside of the unit and prevent the …

    Get Price
  • Series 63 Series 64 - PB Heat: Peerless® Boilers

    2020-8-11u2002·u2002Packaged or Knockdown, Hot Water or Steam Boilers ... *Draft hood outlet and vent damper are 7' diameter on 63-04L and 63.04. These models are also certified in USA with 6' vent using vent reducer provided in draft hood carton. Install reducer on outlet of vent damper. Title:

    Get Price
  • 4th Class Power Engineering Unit A11: Introduction to ...

    Start studying 4th Class Power Engineering Unit A11: Introduction to Boiler Designs. Learn vocabulary, terms, and more with flashcards, games, and other study tools.

    Get Price